Parts & Accessories

:
:

[«] 2 3 4 5 6 7 8 9 10 [»]

Product Code  Name  Description 
PC/LCA/100 Loading Cassette for RSC 230 & 350L Autoclaves Loading Cassette for RSC 230 & 350L Autoclaves
The Loading Cassette is designed to be used with a Priorclave loading Trolley to transfer the load from different areas of the laboratory to the Priorclave. The Loading Cassette is then inserted into the chamber of the Priorclave reducing the manual handling aspects to a minimum.
Enquire
PC/LCA/200 Loading Cassette for RSC 450 & 700L Autoclaves Loading Cassette for RSC 450 & 700L Autoclaves
The Loading Cassette is designed to be used with a Priorclave loading Trolley to transfer the load from different areas of the laboratory to the Priorclave. The Loading Cassette is then inserted into the chamber of the Priorclave reducing the manual handling aspects to a minimum.
Enquire
PC/LOC/000 Setting Lock Key-switch Facility Setting Lock Key-switch Facility
To prevent unauthorised setting of cycle parameters. A second, 2 position key-switch is fitted. When in the locked position, the key can be removed and no alteration can be made to the Temperature, Time and Option Select settings.
This function is included as part of the 5 and 10 program memory options.
Enquire
PC/LPT/000 Load Sensed Process Timing Load Sensed Process Timing
A wandering temperature probe, which can be positioned in the place that is potentially the coolest part of the load. The sterilising timer is held until the wandering probe reaches the desired temperature. The control of the chamber temperature is not affected by this option as it is controlled from a separate probe.
If the Priorclave Data Printer is fitted, the Load Sensed Process Timing option also provides a second temperature printout, recording the temperatures registered by the wandering probe.
Enquire
PC/MED/000 Media Warming Facility Media Warming Facility
When selected the autoclave is held at a temperature between 40oC and 50oC (to maintain a media load in a liquid state for easy pouring. Particularly useful when combined with the delayed start facility. Fitted as standard to all Priorclaves.
Enquire
PC/MED/COO Accelerated Media Cooling Option Accelerated Media Cooling Option
During the cooling phase of the autoclave cycle the autoclave is kept sealed, by preventing the usual drawing in of air through the air purge valve at just below 100oC. This leads to a slow build up of a vacuum in the chamber, considerably enhancing the cooling rate of the load. The process is gradual and so there is very little loss of load volume. A major advantage compared with air ballast cooling and water spray cooling is that there is no risk of contamination from outside of the autoclave.
This option includes a 5-program memory, allowing the option to be selected on or off according to the type of program selected.
Enquire
PC/MID/SSB Stainless Mesh Basket Compact 40 Stainless Mesh Basket Benchtop Compact Priorclaves
Ideal for sterilising many small items, which are best sterilised within a container. Dimensions 250 x 325 x 140 mm (wxdxh).
Enquire
PC/MID/SSD Stainless Steel Discard Container Compact 40 Stainless Steel Discard Container Benchtop Compact Priorclaves
Liquid tight, stainless steel container for increased cleanliness, hygiene and protection of heaters from media and plastic spillage when sterilising ÔdiscardÕ loads.
Dimensions 220 x 400 x 105 mm (wxdxh)
Enquire
PC/MID/TLY Compact 40 Autoclave Mounting Trolley Compact 40 Benchtop Autoclave Mounting Trolley
Manufactured from epoxy coated mild steel with a stainless steel top, this mounting trolley is fitted with four castors, two of which are lockable, an integral lower storage shelf and an integral drip tray and collection bottle for condensate. Designed to give the optimum loading height for Compact Benchtop Priorclaves.
Approximate Overall Dimensions: 600 x 700 x 800mm (wxdxh)
Enquire
PC/MID/VDY Post Cycle Drying, Compact Priorclaves Post Cycle Drying, Compact Priorclaves
Used in conjunction with the Combined Pre Cycle Vacuum and Vacuum Cooling options and when properly set up, this provides the facility to dry a suitable load.
At the end of the process time the autoclave is rapidly drained and vented and a series of vacuum pulses applied. The chamber walls are heated by strategically placed externally mounted silicone mat contact heaters. The duration and number of vacuum pulses can be programmed for individual cycles to suit particular load types.
A Waterfill System is included as part of this option along with an Air Intake Filter
Note: Chamber drain requires a maximum drain height of 50mm.
Enquire
PC/OHD/QCS Opposite Hand Opening Door Option Front Loading QCS Models Opposite Hand Opening Door Option Front Loading QCS Models
Front Loading Priorclaves are normally hinged on the left hand side for ease of operation with the right hand. Use this option to specify a door hinged on the right hand side if required to fit your room layout or preference.
Enquire
PC/OHD/RSC Opposite Hand Opening Door - RSC Autoclaves Opposite Hand Opening Door - RSC Autoclaves
Front Loading Priorclaves are normally hinged on the left hand side for ease of operation with the right hand. Use this option to specify a door hinged on the right hand side if required to fit your room layout or preference.
Enquire

[«] 2 3 4 5 6 7 8 9 10 [»]